Trane Furnace: Air for combustion and ventilation in non-direct vent installs
Air for combustion and ventilation in non-direct vent installs on a Trane furnace: On non-direct vent UH1/DH1 installs the furnace draws combustion air from the room, so the air openings have to stay open and clear. Starving a furnace of air can cause poor combustion, flame rollout or carbon monoxide, so confirm the supply before leaving, and have a licensed installer size anything in doubt.
Applies to: Non-direct vent UH1/DH1 furnaces
Common causes of air for combustion and ventilation in non-direct vent installs
- Not a fault call. Combustion air requirement for non-direct vent installs.
How to fix air for combustion and ventilation in non-direct vent installs: step by step
- Confirm combustion air openings are free of anything that restricts airflow.
- Plan for future remodels so the furnace room keeps free airflow and openings do not get blocked.
- Size and provide air per the National Fuel Gas Code, ANSI Z223.1 / CAN/CGA B149.1, or local code.
- Consider mechanical exhaust fans and fireplaces, which can disturb furnace operation by pulling air out of the room.
- After the install, check draft and flame behaviour with the exhaust fans running.
- Test for carbon monoxide at the vent and in the living space.
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.