Rheem Furnace: Non-communicating condenser wiring
Non-communicating condenser wiring on a Rheem furnace: A non-communicating condenser or heat pump used with a communicating furnace and thermostat needs a special configuration.
Applies to: 96V and 96MDV communicating furnaces with non-communicating condensers
How to fix non-communicating condenser wiring: step by step
- Run four dedicated wires (E1, E2, R and C) from the furnace to the condenser.
- Use a daisy-chain layout only; a star layout is not approved.
- Wire the thermostat using the non-communicating condenser diagram.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
More commissioning tips for furnace
Source: 96V installation instructions, p. 100. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.