Rheem Furnace: Moving the line voltage junction box to the other side
Moving the line voltage junction box to the other side on a Rheem furnace: Only do this with the furnace disconnected from line voltage. The door switch moves with the junction box.
Applies to: Electrical junction box relocation
How to fix moving the line voltage junction box to the other side: step by step
- Make sure the furnace is not connected to line voltage.
- Disconnect the wires from the door switch.
- Remove the two screws holding the junction box; leave its wires connected.
- Remove the 7/8 in. plug from the opposite hole and drill two 3/16 in. holes at the marked dimples.
- Mount the junction box on the opposite side using the same two screws; use only blunt-tip screws.
- Move the plug to the old location and install two 1/4 in. plugs from the parts bag in the empty holes.
- Squeeze the door switch retaining arms with a flat screwdriver and pry the door switch out.
- Install the door switch in the opposite opening and reconnect the wires.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 76-77. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.