Rheem Furnace: Massachusetts side-wall vent: CO detectors and warning sign
Massachusetts side-wall vent: CO detectors and warning sign on a Rheem furnace: For side-wall horizontal vent terminations less than 7 ft above grade in Massachusetts homes, a hard-wired CO detector with battery backup must be on the floor where the furnace is installed, and a battery or hard-wired CO detector on each additional level. Detectors must meet NFPA 720 and ANSI/UL 2034 and be IAS certified. A metal or plastic sign at least 8 ft above grade, in line with the vent, must read GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS, with letters at least 1/2 inch. If the detectors cannot be installed at completion, the owner has 30 days, and a battery-operated CO detector must be installed in the meantime.
Applies to: Side-wall horizontally vented installations in Massachusetts
How to fix massachusetts side-wall vent: co detectors and warning sign: step by step
- Confirm a hard-wired CO detector with battery backup is on the furnace floor level.
- Confirm a CO detector is installed on each additional level served.
- Confirm the warning sign is mounted at least 8 ft above grade, in line with the vent terminal.
- Leave the installation manual and venting parts list with the appliance.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.