Rheem Furnace: Horizontal left/right with right vent: remove elbow, trap and factory plugs

Updated · by Aurora Star Tech Inc.

Horizontal left/right with right vent: remove elbow, trap and factory plugs on a Rheem furnace: First round of work when converting a 96V to horizontal with the vent on the right. Pull parts, keep some, toss some. Keep your pile organized. Elbow and couplings get reused, so do not lose them. Plugs move around, and a missed plug means a leak later.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Horizontal left/right with right vent

Common causes of horizontal left/right with right vent: remove elbow, trap and factory plugs

  • Converting upflow furnace to horizontal left or right with right-side venting
  • Condensate trap and hoses need to come off to change orientation
  • Factory plugs need moving to match the new vent and drain layout
  • Parts bagged and tagged for re-use

How to fix horizontal left/right with right vent: remove elbow, trap and factory plugs: step by step

  1. Remove the elbow, both couplings and the flue transition. Keep the elbow and couplings
  2. Remove the condensate trap and hoses. Remove the two trap screws and pull the trap straight out. Keep hose D
  3. Install the 2-5/8 in flush mount plug
  4. Remove the left 2-3/8 in flush plug in the blower shelf and discard it
  5. Move the right 2-3/8 in flush mount plug from the blower shelf to the top plate
  6. Move the 0.403 in drain plug from the collector box to its new location
  7. Remove the rectangle flush mount plug and discard it
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

96V

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

96MDV

96MDV06096MDV07096MDV08596MDV100

Source: Rheem 96V installation manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977