Downflow non-zero clearance on the right side on a Rheem furnace: For downflow non-zero clearance installs, the minimum right-side clearance is shown in Figure 4. If that clearance cannot be kept, a downflow zero-clearance kit RXGY-ZK must be installed.
Applies to: Downflow installations
How to fix downflow non-zero clearance on the right side: step by step
- Check the right-side clearance against Figure 4.
- If the clearance cannot be met, install zero-clearance kit RXGY-ZK.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.