Rheem Furnace: Condensate drain connection options
Condensate drain connection options on a Rheem furnace: Condensate drain has options for 3/4 in. or 1/2 in. PVC connections. The trap also accepts a 5/8 in. rubber hose with a hose clamp when mounted inside the unit. Improper hose connections will stop condensate from draining and may damage the furnace. The trap has two sides, so note the inlet and outlet locations when converting.
Applies to: All conversions
How to fix condensate drain connection options: step by step
- Select 3/4 in. or 1/2 in. PVC, or a 5/8 in. hose with clamp for an internal trap.
- Confirm the trap inlet and outlet sides match the conversion.
- Confirm the drain connection allows condensate to drain freely.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.