Goodman Furnace: Upflow vertical – drain exiting left side

Updated · by Aurora Star Tech Inc.

Upflow vertical - drain exiting left side on a Goodman furnace: Routing the condensate drain out the left side of an upflow furnace uses a hose and fitting kit. The hose cut point depends on the cabinet width, so measure and confirm before cutting.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Upflow vertical, left side drain

Common causes of upflow vertical - drain exiting left side

  • Furnace installed with the drain on the left side
  • Hose cut at the wrong line for the cabinet width
  • Clamp loose or wrong size, leaking
  • Fitting installed backwards, barb outside

How to fix upflow vertical - drain exiting left side: step by step

  1. Install the 45 degree pipe/hose coupling through the left side hole, barb end inside. Secure with two #8 self-tapping screws.
  2. Cut hose #3 at line B for a 17.5 in cabinet, at line C for a 21 in cabinet, or do not cut for a D width cabinet. Confirm the cabinet width first.
  3. Connect the large end of hose #3 to the trap outlet with a 1.25 in clamp.
  4. Connect the small end of hose #3 to the 45 degree elbow with a 1 in clamp.
  5. Connect the field drain to the furnace trap outlet per the field drain section.
  6. Pour water through and check for leaks at the clamps.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Furnace codes

Source: Goodman GMVC96 service manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.