Goodman Furnace: Thermostat setup: single stage heat and cool

Updated · by Aurora Star Tech Inc.

Thermostat setup: single stage heat and cool on a Goodman furnace: The furnace needs only Y for cooling and W for heating. Set the thermostat to single stage heat / single stage cool and do not use multi stage mode.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All systems with this control

How to fix thermostat setup: single stage heat and cool: step by step

  1. Set the thermostat to single stage heat / single stage cool.
  2. Confirm 24VAC on Y for cool calls and on W for heat calls.
  3. Do not set the thermostat to heat pump mode. The only exception is a non-communicating single stage heat pump, which needs heat pump mode with the reversing valve on in cooling.
  4. Do not use an O wire; this system has no reversing valve input.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Furnace codes

More commissioning tips for furnace

Source: Goodman GMVC96 service and troubleshooting manual, p. 25, 29, 30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.