Goodman Furnace: Condensate drainage system check
Condensate drainage system check on a Goodman furnace: On these condensing Goodman furnaces the drain tubes, trap and field drain line need to be checked every year and cleaned as often as needed so condensate can leave freely. This is a job for a qualified servicer. Before opening anything, shut off power to the furnace so a pressure switch or inducer cannot start during the work.
Applies to: All 34.5in chassis gas furnaces
Common causes of condensate drainage system check
- Blocked drain tubes or trap from sludge and debris, which backs water up into the furnace
- Blocked field supplied drain line, often from sediment, algae or a pinched or sagging run
How to fix condensate drainage system check: step by step
- Turn the power off at the disconnect before disconnecting any drain hose.
- Check the drain tubes, trap and field drain line for blockage.
- Clean the drain tubes, trap and drain line as needed, and refit them correctly.
- Check for leaks at the hose connections at and inside the furnace.
- After reassembly, restore power, run a heat cycle and watch the drain to confirm it flows and nothing weeps.
- If the furnace has been shutting down on a water level problem, tell the homeowner it is a yearly maintenance item.
If the unit shows an error code, look it up: Goodman Furnace codes
Source: Goodman GMVC96 service and troubleshooting manual, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.