Goodman Furnace: Check auxiliary limit control (blower housing)
Check auxiliary limit control (blower housing) on a Goodman furnace: There are two auxiliary limits on the blower housing, one on each side, and they can be manual or automatic reset. Their job is to stop the burners if the main blower fails or if power is lost while the furnace is firing. They work in horizontal right, horizontal left and counterflow installs without being relocated. Before testing, make sure the power is off and the furnace has cooled. A limit that is open should be treated as a symptom, because something made the housing hot, and that cause needs to be found.
Applies to: Auxiliary limit on blower housing
Common causes of check auxiliary limit control (blower housing)
- Main blower failure in horizontal or counterflow installs
- Power interruption while the furnace is firing
- Overheating from restricted airflow (open limit)
- Loose or damaged wire on the limit terminals
How to fix check auxiliary limit control (blower housing): step by step
- Shut off power at the disconnect and confirm it is off with a meter before touching anything
- Remove the wires from the auxiliary limit terminals
- Test continuity across the two terminals with an ohmmeter, only at room temperature, since a hot limit will read open and mislead you
- If the limit is open, press the red reset button one time only
- If it opens a second time, find out why before resetting again. Check blower operation, filter and ductwork
- Repeated resets without finding the cause can damage the heat exchanger, so do not keep pushing the button
- Reconnect the wires and run a full cycle to confirm normal operation
If the unit shows an error code, look it up: Goodman Furnace codes
Source: Goodman GMVC96 service manual, p. 48-49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.