Goodman Furnace: Bypass the inductor to test an ECM motor
Bypass the inductor to test an ECM motor on a Goodman furnace: The inductor is in the line power supply to the motor. If it has failed, the motor will not run.
Applies to: 3/4 and 1 HP ECM motors with inductor
How to fix bypass the inductor to test an ecm motor: step by step
- Disconnect the black line wire from the inductor.
- Connect that wire directly to the motor.
- If the motor runs, replace the inductor.
If the unit shows an error code, look it up: Goodman Furnace codes
Source: Goodman GMVC96 service and troubleshooting manual, p. 44. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.