Goodman Furnace: Blower motor does not have enough information, fails to start 40 consecutive times

Updated · by Aurora Star Tech Inc.

Blower motor does not have enough information, fails to start 40 consecutive times on a Goodman furnace: The blower motor failed to start 40 times in a row, and the control says it lacks the information to run it properly. That can mean a data problem in the control module or a rotor that is locked up. Shut off power and confirm the circuit is dead before opening up the blower compartment.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 34.5 in chassis gas furnaces

Common causes of blower motor does not have enough information, fails to start 40 consecutive times

  • Error with the integrated control module, such as missing or wrong shared data
  • Motor has a locked rotor condition

How to fix blower motor does not have enough information, fails to start 40 consecutive times: step by step

  1. Turn power off before repair and confirm it with a meter.
  2. Check the integrated control module and verify it holds the correct shared data set.
  3. Check for a locked rotor condition by turning the wheel by hand, and correct it.
  4. Use the memory card for the specific model if data needs to be reloaded.
  5. Replace the motor with the correct replacement part if needed.
  6. Restore power and confirm the blower starts normally.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Furnace codes

Source: Goodman GMVC96 Service and Troubleshooting, p. 63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977