Goodman Furnace: Airflow display in the Status Menu
Airflow display in the Status Menu on a Goodman furnace: When the blower runs, the first 7-segment character shows A. The next two show the CFM divided by 100, rounded to the nearest 100 CFM. For example, 550 to 649 CFM shows A06 and 1150 to 1249 CFM shows A12.
Applies to: All 34.5in chassis furnaces
If the unit shows an error code, look it up: Goodman Furnace codes
Source: Goodman GMVC96 service and troubleshooting manual, p. 35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.