Allied Furnace: Return air connection and sealing
Return air connection and sealing on a Allied furnace: Improper return connections can allow combustion products into the living space.
Applies to: Upflow and horizontal installations with return air
Common causes of return air connection and sealing
- Return ducts connected to the back of the furnace
- Gaps or leaks in the base or platform
- Return air shared with a fireplace or stove
How to fix return air connection and sealing: step by step
- Do not connect return air ducts to the back of the furnace.
- Seal the return air system to the furnace with sheet metal screws and joint tape.
- Seal the furnace airtight to the return plenum in platform installs.
- Do not use a door as part of the return air duct system.
- Make sure the base gives stable support with no sagging, cracks or gaps.
- Do not connect return or supply ducts to other heating devices such as a fireplace or stove.
- For side return, cut only within the cabinet markings and keep the opening within the stated dimensions.
If the unit shows an error code, look it up: Allied Furnace codes
Source: Allied 92G1UH installation instructions manual, p. 10, 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.