NTI error code Hold 110 on a boiler means: Ignition failure occurred. It is also called NTI diagnostic code Hold 110.

Critical severityBoilerTrinity Tft

Homeowner? What NTI code Hold 110 means for you

Stop and call Your boiler is reporting: Ignition failure occurred. This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does NTI error code Hold 110 mean?

Burner did not prove flame after the full set of ignition attempts (three retries).

Applies to: Trinity Tft60, Tft85, Tft110, Tft154, Tft201, Tft285, Tft340, Tft399

Common causes of NTI code Hold 110

  • Spark igniter gap wrong or igniter faulty
  • Spark cable off the spark generator or igniter, or green ground wire off the 1/4 in tab
  • Blocked exhaust, air inlet, blower, gas valve venturi or heat exchanger

A technician checks these and 7 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

NTI models that use code Hold 110

Tft60Tft60Tft85Tft85Tft110Tft110Tft154Tft155Tft175Tft200Tft201Tft250Tft285Tft300Tft340Tft399Tft399

Other NTI Boiler codes

CodeMeaning
Hold 95Stack sensor fault
Hold 96Outdoor sensor fault
Hold 96Outdoor sensor fault
Hold 100Pressure sensor fault
Hold 100Pressure sensor fault
Hold 110Ignition failure occurred
Hold 111Flame current lower than WEAK threshold
Hold 111Flame current lower than WEAK threshold
Hold 118Controller interaction system fault
Hold 119Controller interaction communications fault
Hold 124High fire switch OFF
Hold 124High fire switch OFF

All NTI Boiler error codes →

NTI code Hold 110: homeowner questions

What does NTI code Hold 110 mean?

Ignition failure occurred. Burner did not prove flame after the full set of ignition attempts (three retries).

Is it safe to keep using my boiler with code Hold 110?

No. Code Hold 110 is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset NTI code Hold 110 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix NTI code Hold 110 near me?

Aurora Star Tech Inc. repairs NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: NTI Trinity Tft399 Installation and Operation Manual (2018-09-07), Sec. 16.0 Troubleshooting, Table 16-3. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.