Lennox Gas Fireplace: Run the fireplace during a power outage
Run the fireplace during a power outage on a Lennox gas fireplace: 4 AA batteries in the backup holder keep the flame ON/OFF working without 120 V.
Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)
How to fix run the fireplace during a power outage: step by step
- Remove the surround (if fitted) and the door.
- Pull the battery holder out on its cable from the IPI/CPI bracket on the left side.
- Load 4 AA batteries (flat end to the spring), put the holder back, refit the door.
- If the receiver batteries are dead too, slide the receiver to ON to light it by hand.
If the unit shows an error code, look it up: Lennox Gas Fireplace codes
Models
More other tips for gas fireplace
Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Field Wiring p.25-26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.