Viessmann Error Code PC0L: Outdoor temperature too low (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC0L on a mini-split means: Outdoor temperature too low. It is also called Viessmann diagnostic code PC0L.

Low severityMini-SplitViessmann Vitocal 200-S DLCM(R/H)B multi-zone outdoor · Viessmann DLFSHB high wall indoor

Homeowner? What Viessmann code PC0L means for you

Usually minor Your ductless mini-split is reporting: Outdoor temperature too low. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC0L mean?

Outdoor air is below the range the unit is allowed to run in, so it stops (protection, not a part failure). Outdoor board shows LP; 48K HH shows P3 in heating.

Applies to: DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)

Common causes of Viessmann code PC0L

  • Very low outdoor temperature
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PC0L

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Viessmann Mini-Split codes

CodeMeaning
P2Compressor top overheat (OLP)
P3Low outdoor temperature cut-off in heating
P4Compressor drive fault
P7IPM temperature sensor fault
PC0ACondenser high temperature protection
PC0FPFC module protection
PC00Inverter module (IPM) protection
PC02Compressor top overheat (OLP)
PC03Pressure protection
PC04Inverter compressor drive error
PC06Discharge temperature protection
PC08Outdoor over-current protection

All Viessmann Mini-Split error codes →

Viessmann code PC0L: homeowner questions

What does Viessmann code PC0L mean?

Outdoor temperature too low. Outdoor air is below the range the unit is allowed to run in, so it stops (protection, not a part failure). Outdoor board shows LP; 48K HH shows P3 in heating.

Is it safe to keep using my ductless mini-split with code PC0L?

Usually yes. Code PC0L is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code PC0L myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC0L comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC0L near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26; Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.