Midea Error Code Eh61: Indoor coil sensor (T2) fault (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code Eh61 on a mini-split means: Indoor coil sensor (T2) fault. It is also called Midea diagnostic code Eh61.

Medium severityMini-SplitMidea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code Eh61 means for you

Check, then call Your ductless mini-split is reporting: Indoor coil sensor (T2) fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code Eh61 mean?

Indoor coil sensor T2 open or shorted.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Common causes of Midea code Eh61

  • Sensor plug loose
  • Bad T2 sensor
  • Bad indoor PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code Eh61

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
EH00Indoor EEPROM error
EH02Zero-crossing signal error
EH03Indoor fan speed out of range
EH30Indoor external fan low voltage
EH31Indoor external fan over voltage
Eh60Room sensor (T1) fault
EL0CRefrigerant leak detected
EL01Indoor / outdoor communication error
F0Current overload protection
F1Outdoor ambient sensor (T4) fault
F2Condenser coil sensor (T3) fault
F3Discharge sensor (T5) fault

All Midea Mini-Split error codes →

Midea code Eh61: homeowner questions

What does Midea code Eh61 mean?

Indoor coil sensor (T2) fault. Indoor coil sensor T2 open or shorted.

Is it safe to keep using my ductless mini-split with code Eh61?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code Eh61 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code Eh61 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code Eh61 near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17, p.30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.