Rheem Furnace: Reset a soft lockout (R95P)
Reset a soft lockout (R95P) on a Rheem furnace: Soft lockouts can be cleared by cycling the heat call or power. A 1-hour lockout also resets on its own after one hour; a hard lockout (code 93) needs a power reset; code 61 hard lockout can be reset by cycling the heat call.
Applies to: R95PA040, 060, 070 (1317MSA), R95PA085, 100 (1521MSA), R95PA115 (1524MSA); (-)95P series
How to fix reset a soft lockout (r95p): step by step
- Cycle the heat call off for 2 to 20 seconds, or cycle power
- Code 93 hard lockout: cycle power
If the unit shows an error code, look it up: Rheem Furnace codes
Models
R95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA
Source: Rheem (-)95P Series single-stage condensing furnace Installation Instructions 92-24161-111-03, Sequence of Operation and Lockout, p.90-92. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.