Carrier Furnace: Show supply and return air temperature on the display (59MN7C)
Show supply and return air temperature on the display (59MN7C) on a Carrier furnace: The t° menu item turns on a rotating display of mode, supply air temperature (SAT), return air temperature (RAT) and the difference. Default is off; it only shows while heating, cooling or heat pump operation is running.
Applies to: 59MN7C modulating furnace
How to fix show supply and return air temperature on the display (59mn7c): step by step
- Scroll to t° in the main menu
- Choose F or C (or off)
- If the displayed SAT does not agree with a thermometer, move the SAT sensor further from the furnace or past a bend in the duct
If the unit shows an error code, look it up: Carrier Furnace codes
Models
59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--22
More settings shortcuts tips for furnace
Source: Carrier 59MN7C installation instructions, Temperature Display, Table 18, p.47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.