Rinnai Boiler: Hot water works, no central heating
Hot water works, no central heating on a Rinnai boiler: DHW is available but there is no space heating.
Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP
Common causes of hot water works, no central heating
- CH program key off
- On/off room thermostat sending no call
- RS100 with outdoor sensor: outdoor temperature above the Eco setting (default 70 F)
- Three-way valve not going to CH position
How to fix hot water works, no central heating: step by step
- Switch central heating on.
- Check the room thermostat.
- With RS100, check INFO step 7 and the timer and room temperature settings.
- Check three-way valve wiring; replace the valve motor if needed.
If the unit shows an error code, look it up: Rinnai Boiler codes
Models
I-Series Plus 150K and smaller
I-Series Plus 175K and higher
Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.77 (15.4). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.