York Error Code LAST ERROR button: Read or clear the stored fault codes (Furnace)
York error code LAST ERROR button on a furnace means: Read or clear the stored fault codes. It is also called York diagnostic code LAST ERROR button.
Homeowner? What York code LAST ERROR button means for you
Usually minor Your furnace is reporting: Read or clear the stored fault codes. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does York error code LAST ERROR button mean?
The board keeps up to five fault codes, newest first, even after power loss. Solid-LED errors are not stored. Retrieval only works when no thermostat signal is active.
Applies to: York IFC boards with LAST ERROR button
York models that use code LAST ERROR button
TM9V040A10TM9V060B12TM9V080B12TM9V080C16TM9V100C16TM9V100C20TM9V120D20
Other York Furnace codes
All York Furnace error codes →
York code LAST ERROR button: homeowner questions
What does York code LAST ERROR button mean?
Read or clear the stored fault codes. The board keeps up to five fault codes, newest first, even after power loss. Solid-LED errors are not stored. Retrieval only works when no thermostat signal is active.
Is it safe to keep using my furnace with code LAST ERROR button?
Usually yes. Code LAST ERROR button is normally minor, but if it keeps coming back have it checked.
Can I reset York code LAST ERROR button myself?
You can try one reset (power off for 30 seconds, then on). If York code LAST ERROR button comes back, the cause is still there and a licensed technician should check it.
Who can fix York code LAST ERROR button near me?
Aurora Star Tech Inc. repairs York furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: York service letter ST-028-07 White Rodgers/Emerson IFC boards, Fault Code Sheet, p.5-7; York service tip ST-045-09 UTEC IFC boards, Fault Code Sheet; York TM9V installation manual 1083294-UIM-A-0114, Fault Code Storage and Retrieval, p.42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.