Weil-McLain Heat Pump: Verify heating and DHW operation (System Types B and C)
Verify heating and DHW operation (System Types B and C) on a Weil-McLain heat pump: Test each zone and DHW call with the thermostat or DHW input.
Applies to: ECO HP System Types B and C
Common causes of verify heating and dhw operation (system types b and c)
- Outdoor temperature is outside the T4HMAX/T4HMIN limits, so the heat pump will not run.
How to fix verify heating and dhw operation (system types b and c): step by step
- Make a thermostat call. The ECO HP should run and begin heating.
- If it does not run, check that outdoor temperature is inside the limits. Temporarily adjust T4HMAX and T4HMIN to test, then restore application settings.
- For System Type B, the SG terminals on the HP IDU control board can force AHS calls. No thermostat or DHW call can do this. Close the contacts and the boiler should receive a call for heat.
- Refer to the boiler manual for startup checks.
- Repeat the tests for each zone or DHW call.
If the unit shows an error code, look it up: Weil-McLain Heat Pump codes
Source: ECO HP Heat Pump Application Guide, pp. 62. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.