Weil-McLain Heat Pump: System Type B, Application B2 design requirements
System Type B, Application B2 design requirements on a Weil-McLain heat pump: Primary/secondary multi-zone layout with two space heating zones and one DHW zone, controlled through the DHW-priority zone panel. The boiler has one priority and reset curve because the AHS is a single output.
Applies to: System Type B, Application B2 (primary/secondary)
How to fix system type b, application b2 design requirements: step by step
- Pipe the system primary/secondary.
- Place the boiler downstream of the heat pump so high return temperatures do not shut the heat pump down when both run together.
- Size the zone circulators for the required flow.
- Provide space heating and DHW zone circulators (installer supplied). Add more zone panels for additional zones.
- Note that the boiler circulator ships loose and the heat pump circulator is installed in the heat pump manifold.
- Make sure all zones run safely at supply temperatures up to 149°F, or add mixing valves.
- If boiler reset is used, check that the DHW supply temperature curve is sufficient for DHW operation, or use a single boiler target temperature instead (confirm with ECOCalc).
- Set the boiler and heat pump controls using the boiler manual and heat pump page 11 navigation.
If the unit shows an error code, look it up: Weil-McLain Heat Pump codes
Source: ECO HP Heat Pump Application Guide, p. 30. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.