Weil-McLain Heat Pump: System Type A: Unity 2.0 boiler as master, ECO HP as shadow
System Type A: Unity 2.0 boiler as master, ECO HP as shadow on a Weil-McLain heat pump: The boiler decides when the heat pump and boiler run. Up to 4 zones are supported, depending on system requirements and the boiler's field wiring limits. Extra zones need a DHW-priority zone panel such as the Thermostat Interface Unit. Zone calls go to the boiler inputs. The heat pump runs when the boiler's AHD contacts close and are wired to the heat pump thermostat input. DHW calls come through the boiler's second AHD contact. The heat pump controls its own circulator; the boiler or zone board controls all other circulators. Combi boilers may not suit the master role because input/output pairs 1 and 4 are used for 3-way valve operation.
Applies to: System Type A
How to fix system type a: unity 2.0 boiler as master, eco hp as shadow: step by step
- Wire the boiler's AHD1 contact to the heat pump thermostat input.
- Wire the boiler's AHD2 contact for DHW calls.
- Connect zone thermostat calls to the boiler inputs; use a zone panel for zones beyond the boiler's inputs.
- Check whether a Combi boiler is the intended master, since outputs 1 and 4 may be used for 3-way valve operation.
If the unit shows an error code, look it up: Weil-McLain Heat Pump codes
Source: ECO HP Heat Pump – Application Guide, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.