Updated · by Aurora Star Tech Inc.

DHW function on the ECO HP on a Weil-McLain heat pump: The ECO HP has no adjustable DHW settings. When the EVU contacts close, the unit runs in DHW mode, targeting the highest outlet water temperature it can reach. DHW takes priority over a heating call and runs until the call is removed. In Type A systems, the Max On Time is set in the Unity 2.0 control and limits the DHW call before heating priority runs. In Type B and C systems, the DHW-priority zone panel (such as the Weil-McLain Thermostat Interface Unit) has a fixed 1 hour timer, after which heating zones can run.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO HP domestic hot water operation

How to fix dhw function on the eco hp: step by step

  1. Do not look for a DHW setting on the ECO HP; adjust Max On Time in the Unity 2.0 control for Type A systems.
  2. For Type B and C systems, allow for the fixed 1 hour DHW-priority timer on the zone panel.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Heat Pump codes

Source: ECO HP Heat Pump – Application Guide, p. 13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.