Weil-McLain Heat Pump: Application A1: multi-zone space heating with DHW as zone
Application A1: multi-zone space heating with DHW as zone on a Weil-McLain heat pump: Three space heating zones and one DHW zone run through the Unity 2.0 controlled boiler. DHW has priority, so space heating is disabled during a DHW call from the indirect tank. If the boiler runs with the heat pump, the boiler must be downstream of the heat pump to keep high water temperature away from the heat pump inlet. Piping must be primary/secondary.
Applies to: System Type A1
How to fix application a1: multi-zone space heating with dhw as zone: step by step
- Pipe the boiler downstream of the ECO HP.
- Pipe the system as primary/secondary.
- Size the DHW circulator for the pressure drop through the indirect tank and piping; large indirect heaters may need different piping.
- Size the zone circulators for the required flow.
- For alternate wiring, use a DHW-priority zone panel such as the Thermostat Interface Unit.
- Note that ECO Tec boilers have an internal boiler circulator.
- The heat pump circulator is installed in the heat pump manifold and comes in the heat pump accessory box.
- Set the boiler controls per the boiler control table on page 20 and the heat pump controls per page 21; navigate the heat pump menu per page 11.
If the unit shows an error code, look it up: Weil-McLain Heat Pump codes
Source: ECO HP Heat Pump – Application Guide, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.