Weil-McLain Boiler: Zoning: two space heating zones plus DHW piped directly to boiler
Zoning: two space heating zones plus DHW piped directly to boiler on a Weil-McLain boiler: Two heating thermostats on PRIORITY 2 and a DHW aquastat on PRIORITY 1.
Applies to: SlimFit Series 3 550/750 single boiler
How to fix zoning: two space heating zones plus dhw piped directly to boiler: step by step
- Check the 120 VAC outputs (page 60) and 24 VAC inputs (page 52).
- Connect space heating thermostats to INPUT 2 and INPUT 3. Keep both assigned to PRIORITY 2.
- Connect the DHW aquastat to INPUT 1 and assign INPUT 1 to PRIORITY 1 (factory DHW default).
- In the Wizard or the PRIORITY 2 menu, select the matching space heating system type.
- Use the factory DHW defaults or change them as needed.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: SlimFit Series 3 boiler manual, p. 64. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.