Weil-McLain Boiler: Zoning: three space heating zones with circulators (no DHW)
Zoning: three space heating zones with circulators (no DHW) on a Weil-McLain boiler: Three thermostat zones each with its own circulator, all on PRIORITY 2.
Applies to: SlimFit Series 3 550/750 single boiler
How to fix zoning: three space heating zones with circulators (no dhw): step by step
- Check the 120 VAC outputs (page 60) and 24 VAC inputs (page 52) in the wiring section.
- Connect thermostats to P11-4/5, P15-1/2 and P15-3/4.
- Connect circulators to the P2 outputs.
- Confirm inputs 1, 2 and 3 are assigned to PRIORITY 2 (factory default).
- In the Wizard or the PRIORITY 2 menu, select the heating system type that matches the installed system.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: SlimFit Series 3 boiler manual, p. 64. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.