Weil-McLain Boiler: Sidewall vent termination: approved fittings only
Sidewall vent termination: approved fittings only on a Weil-McLain boiler: Sidewall vents may only end with the terminations shown in Figure 14. Other terminations can cause nuisance shutdowns and loss of heat.
Applies to: CGi-25 to CGi-8
Common causes of sidewall vent termination: approved fittings only
- Non-approved termination fitting
- Termination fitting that does not match the vent system
How to fix sidewall vent termination: approved fittings only: step by step
- Use an elbow or vertical tee with screen(s), or an elbow with a termination coupling and screen.
- Match the termination to the vent system type (Saf-T Vent, Z-Vent, FasNSeal or CORR/GUARD) as shown in Figure 14.
- Do not use any other termination type.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: CGi Series 5 boiler manual, p. 25-26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.