Weil-McLain Boiler: Reducing maximum pipe length for extra elbows
Reducing maximum pipe length for extra elbows on a Weil-McLain boiler: Each elbow beyond the allowed count reduces the maximum vent or air length. Use the pipe manufacturer's figure if it is longer.
Applies to: Vent and air piping layout
How to fix reducing maximum pipe length for extra elbows: step by step
- Count all elbows in the vent and air piping, including terminations.
- Allowed without reduction: two elbows in the vent piping and one in the air piping.
- For each extra elbow (45 or 90 degree), reduce 6 in pipe by 15 ft.
- For each extra elbow, reduce 8 in pipe by 7 ft.
- If the pipe maker lists a longer equivalent length for the elbow, use that value.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: SlimFit 1000-2000 Series 2 boiler manual, p. 29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.