Weil-McLain Boiler: Radiators or baseboard cold or noisy (oil water boiler)
Radiators or baseboard cold or noisy (oil water boiler) on a Weil-McLain boiler: Some heat emitters do not heat, or they gurgle.
Applies to: WGO-2 to WGO-9 oil-fired water boilers
Common causes of radiators or baseboard cold or noisy (oil water boiler)
- Air in the system
- System pressure low
- High limit set too low
How to fix radiators or baseboard cold or noisy (oil water boiler): step by step
- Bleed air from the radiator or baseboard vents. Start on the lowest floor and open each vent until water comes out.
- Check system pressure. Normal residential cold fill is about 12 psig. If pressure is low, look for leaks right away and refill.
- Raise the high limit if it is set too low (max 220 F).
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain WGO Series 4 Water Boiler Manual 550-142-331/0225, Troubleshooting p.7; Start-up p.27. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.