Weil-McLain Boiler: Pilot flame signal lost during operation
Pilot flame signal lost during operation on a Weil-McLain boiler: During main burner operation the control monitors pilot flame current. If the signal is lost, the boiler re-ignites automatically.
Applies to: CGi Series 5 spark-ignited pilot boilers
How to fix pilot flame signal lost during operation: step by step
- The main valve closes when the pilot flame signal is lost.
- The spark generator activates.
- The control returns the sequence to the prepurge step to restart ignition.
- If the boiler does not light, check for a lockout and follow the ignition fault reset.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: CGi Series 5 gas-fired water boiler manual, p. 45. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.