Install relief valve and discharge piping on a Weil-McLain boiler: The relief valve mounts on the 3/4 inch nipple in the supply tee. Discharge piping must be safe and clear.
Applies to: All SlimFit boilers
How to fix install relief valve and discharge piping: step by step
- Install the female relief valve on the 3/4 inch nipple in the 2x3/4 inch bushing of the supply tee. Use pipe no smaller than 3/4 inch.
- Pipe the discharge to a safe disposal point.
- Keep the discharge line as short as possible and the same size as the valve outlet along its full length.
- Slope the discharge line down from the valve and end it at least 6 inches above a floor drain where discharge is visible.
- End the line plain (not threaded) and use material rated for 375 °F or higher.
- Do not route the discharge where it can freeze. Do not install any shutoff valve between the valve and boiler or in the discharge line.
- After filling and pressurizing, lift the lever to test. Confirm it discharges freely and replace it if it does not.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: SlimFit 550/750 Series 3 boiler manual, p. 11-12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.