Weil-McLain Boiler: Inspect and fill the condensate trap

Updated · by Aurora Star Tech Inc.

Inspect and fill the condensate trap on a Weil-McLain boiler: The condensate trap must stay filled with water during operation. An empty trap lets flue gas out of the condensate drain.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SVF 500/600 Series 1

Common causes of inspect and fill the condensate trap

  • Trap not filled at startup
  • Empty trap during operation allows flue gas emission

How to fix inspect and fill the condensate trap: step by step

  1. Inspect the condensate drain line, PVC fittings and trap (see p. 61).
  2. Remove the test port cap from the vent adapter.
  3. Pour one cup of clean water into the test port.
  4. Confirm the trap is full of water.
  5. Reinstall the test port cap on the vent adapter.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain SVF 500/600 Series 1 boiler manual, p. 95. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.