Updated · by Aurora Star Tech Inc.

How the 120 VAC relay outputs energize on a Weil-McLain boiler: Each output is paired with an input and a priority. Outputs run only when both conditions are true.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SlimFit 550/750 Series 3 boiler

How to fix how the 120 vac relay outputs energize: step by step

  1. Confirm the input contact is closed for a heat or DHW call.
  2. Confirm the priority assigned to that input/output pair is active.
  3. Wire zone circulators, system pumps, DHW circulators or dampers to Output 1, 2 or 3 as needed.
  4. For AUX PUMP/OUTPUT use, select the operating condition in the control. Settings are covered on pages 75 and 76.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SlimFit Series 3 boiler manual, p. 51. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.