Weil-McLain Boiler: Diaphragm or bladder expansion tank piping (single zone)
Diaphragm or bladder expansion tank piping (single zone) on a Weil-McLain boiler: The expansion tank must be sized for the boiler and system water volume and temperature. Place it on the boiler return piping as close to the boiler as possible, before the circulator inlet. Undersized tanks cause relief valve water loss, makeup water and eventual section failure.
Applies to: CGi-25 to CGi-8
Common causes of diaphragm or bladder expansion tank piping (single zone)
- Undersized expansion tank
- Tank placed on the wrong side of the circulator
How to fix diaphragm or bladder expansion tank piping (single zone): step by step
- Size the tank for the boiler and system water volume and temperature per the tank maker's instructions.
- Install the tank in the boiler return piping as close to the boiler as possible, before the circulator inlet.
- Install an automatic air vent as shown in Figure 15.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: CGi Series 5 boiler manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.