Weil-McLain Boiler: Connect the direct exhaust vent starter

Updated · by Aurora Star Tech Inc.

Connect the direct exhaust vent starter on a Weil-McLain boiler: Attach the vent starter to the blower housing outlet and seal it. Sealant method varies by vent brand.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: CGi-25 to CGi-8

How to fix connect the direct exhaust vent starter: step by step

  1. Select the vent manufacturer and get all components for the location and venting method.
  2. Connect the vent starter from that same manufacturer to the blower housing outlet.
  3. Keep 2 inch clearance from combustibles to the vent pipe.
  4. Seal with the high temperature sealant the vent maker specifies, using a 3/8 inch bead. FasNSeal does not need sealant.
  5. Tighten the band clamp strap until snug around the blower housing.
  6. Put the blower cover back on and fasten it with four screws.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: CGi Series 5 Gas-Fired Water Boiler boiler manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.