Weil-McLain Boiler: Closed-type expansion tank piping (single zone)
Closed-type expansion tank piping (single zone) on a Weil-McLain boiler: Size the closed-type tank for the system volume and temperature. Connect it to the ½-inch NPT tapping behind the supply outlet with ½-inch NPT piping. Pitch horizontal piping up toward the tank at 1 inch per 5 feet.
Applies to: CGi-25 to CGi-8
How to fix closed-type expansion tank piping (single zone): step by step
- Size the tank for the boiler and system water volume and temperature per the tank maker's instructions.
- Connect the tank to the ½-inch NPT tapping behind the supply outlet using ½-inch NPT pipe.
- Pitch horizontal piping up toward the tank at 1 inch per 5 feet.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: CGi Series 5 boiler manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.