Clean the heat exchanger - flue side on a Weil-McLain boiler: Remove the cleanout plate and burner, then clean the flueways.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SlimFit 1000-2000 Series 2

How to fix clean the heat exchanger - flue side: step by step

  1. Follow the shutdown steps: close the external manual gas valve, disconnect power, and let the boiler cool.
  2. Do not drain the boiler unless it will be exposed to freezing; do not drain if freeze prevention fluid is used.
  3. Remove the cleanout plate nuts with a 13 mm wrench or socket.
  4. Remove the cleanout plate carefully to protect its gasket.
  5. Remove the burner, piping end combustion chamber access plate, and blower/venturi/mixing tube assembly (see page 91).
  6. Use the heat exchanger cleaning tool or 20-gauge sheet metal (¾ in wide, about 18 in long) to loosen deposits through the pins at 45° down, 45° up, and horizontal.
  7. Vacuum debris out of the base through the flue inspection opening.
  8. Disconnect the condensate line at the bottom of the heat exchanger and place a pan under the trap connection.
  9. Spray water through combustion chamber openings onto the pins until debris is flushed into the base.
  10. Spray water into the flue inspection opening and through the condensate line.
  11. Reinstall the condensate line and flue inspection plug.
  12. Inspect the cleanout plate gasket and replace it if damaged.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain SlimFit Series 2 boiler manual, p. 102-103. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.