Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Check system and boiler before first start

Updated · by Aurora Star Tech Inc.

Check system and boiler before first start on a Weil-McLain boiler: Checks to complete before starting the boiler and before handing it over.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: CGi-25 to CGi-8

How to fix check system and boiler before first start: step by step

  1. Check system piping for leaks. If found, shut the boiler down and repair immediately.
  2. Vent air from the system with manual vents; air causes poor circulation, uneven heat and noise.
  3. Inspect the vent system for corrosion, physical damage or sagging.
  4. Confirm masonry chimney liners are in good condition, with no obstructions and no openings into the chimney.
  5. Check around the boiler for gas odor using the gas leak check procedure.
  6. Verify operation per the Operation Verification section, then complete the Final Verification Checklist and the installation and service certificate.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: CGi Series 5 boiler manual, p. 64. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977