Weil-McLain Boiler: Check expansion tank
Check expansion tank on a Weil-McLain boiler: Confirm the tank is the correct type, size and charge.
Applies to: SlimFit 550 and 750 Series 3
Common causes of check expansion tank
- Closed-type tank waterlogged: the relief valve weeps often.
- Diaphragm or bladder tank too small or membrane damaged: the relief valve weeps often.
How to fix check expansion tank: step by step
- Check the tank type and location. Open-type tanks sit above the highest radiator or baseboard. Closed-type tanks are welded, sit above the boiler, and are partly filled with water.
- Closed-type tanks need a tank fitting such as the B and G Tank-Trol or Taco Taco-Trol. Do not use automatic air vents on systems with closed-type tanks.
- Diaphragm or bladder tanks need at least one automatic air vent, preferably on top of an air eliminator.
- If the relief valve weeps often, check the tank. For a closed-type tank, check fill level per the fitting maker's instructions, then check tank size and replace with a larger tank if needed.
- For a diaphragm or bladder tank, check that it is large enough. Add tanks if needed. If size is correct, remove it and check charge pressure (usually 12 psig for residential). Replace the tank if it will not hold pressure.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: SlimFit series3 commercial gas-fired water boiler boiler manual, p. 93. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.