Boiler will not start - startup checks on a Weil-McLain boiler: Work through these checks in order before going to the troubleshooting section.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SVF 500/600 Series 1 boilers

Common causes of boiler will not start - startup checks

  • Loose connection or blown fuse
  • Service switch off
  • Gas off at meter or boiler
  • Control settings wrong for application
  • Warm weather shutdown active
  • Thermostats set below room temperature
  • External limit controls open
  • Boiler water above 200°F
  • Closure switch contacts open
  • Incoming gas pressure outside min/max on page 63

How to fix boiler will not start - startup checks: step by step

  1. Check for loose connections, a blown fuse, or a service switch in the off position.
  2. Confirm gas is on at the meter and at the boiler.
  3. Confirm control settings match the application.
  4. Confirm the warm weather shutdown is not active.
  5. Confirm thermostats are set above room temperature.
  6. Confirm external limit controls are closed (if used) and boiler water is below 200°F.
  7. Confirm closure switch contacts are closed.
  8. Confirm incoming gas pressure is within the minimum and maximum on page 63.
  9. If the issue remains, go to the Troubleshooting section starting on page 119.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF 500/600 Series 1 Boiler Manual, p. 98. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.