Viessmann Water Heater: DHW tank maintenance
DHW tank maintenance on a Viessmann water heater: DHW tank and connections need periodic checks. Water treatment equipment must be refilled in time.
Applies to: DHW tank (Vitocell 100 where noted)
How to fix dhw tank maintenance: step by step
- Maintain and clean the DHW tank no later than 2 years after commissioning, then as required.
- Have a qualified heating contractor clean the inside of the tank and DHW connections.
- Refill water treatment equipment (lock or injection system) in good time.
- On Vitocell 100, have the sacrificial anode checked annually with an anode tester.
If the unit shows an error code, look it up: Viessmann Water Heater codes
Source: Vitotronic 200 and 300-K Operating Instructions, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.