Viessmann General: Piping layout with primary heat pump and optional backup heater
Piping layout with primary heat pump and optional backup heater on a Viessmann general: The tank acts as a hydraulic buffer between the heat pump, the backup heat generator and the system loop.
Applies to: Vitocell 100-E MSCA-20-S2 with Vitocal 100-AW AM2V
How to fix piping layout with primary heat pump and optional backup heater: step by step
- Connect the system return to the tank system return port (H).
- Connect the system supply from the highest point port (J) to the system.
- Connect the primary heat/cool generator supply to port D and its return to port G at the lowest point.
- If a backup heat generator is used, connect its supply to port B and its return to port I.
- Leave the injection process plug (F) closed and unconnected.
- Verify all piping and componentry in the field; the drawing is conceptual only.
Source: Vitocell 100-E MSCA-20-S2 Technical Data Manual, p. 6-7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.