Viessmann General: Connecting two remote control units

Updated · by Aurora Star Tech Inc.

Connecting two remote control units on a Viessmann general: Up to two remote controls can go on one boiler control, including a Vitotrol 200A with a Vitotrol 300A. Use a field-supplied junction box or KM BUS distributor and keep the total KM BUS cable length within the limit. For the 200A wiring details, refer to the Vitotrol 200A instructions.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Multiple remote controls on one Vitotronic

How to fix connecting two remote control units: step by step

  1. Connect each unit through a junction box or KM BUS distributor as shown in the diagram.
  2. Keep the total KM BUS cable length to 164 ft (50 m) or less.
  3. Use the Vitotrol 200A installation instructions for that unit's wiring.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Source: Vitotrol 300A installation and service instructions, p. 6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.