Viessmann General: Check network and Internet requirements before commissioning
Check network and Internet requirements before commissioning on a Viessmann general: The Vitoconnect needs a Wi-Fi router, a permanent flat-rate Internet connection and specific open ports. An IT professional should confirm the network on site.
Applies to: Vitoconnect OPTO2 with Wi-Fi router
How to fix check network and internet requirements before commissioning: step by step
- Confirm the Wi-Fi router has Wi-Fi enabled and is protected with WPA2. Unencrypted connections are discouraged.
- Confirm a flat-rate Internet connection with high availability is available, so the Vitoconnect stays connected to the Viessmann server.
- Confirm the network uses dynamic IP addressing (DHCP), as delivered.
- Have an IT professional open outgoing ports 80, 123, 443 and 8883 on the LAN, and set up routing and security if needed.
- Note that the Vitoconnect cannot connect to other servers.
Source: Vitoconnect OPTO2 Installation and Operating Instructions, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.