Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Air Handler: Indoor unit power and signal wiring

Updated · by Aurora Star Tech Inc.

Indoor unit power and signal wiring on a Viessmann air handler: Wire the indoor unit with the power supply and the signal cable, keeping the signal cable separate from refrigerant parts.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLFUAA indoor unit, all sizes

How to fix indoor unit power and signal wiring: step by step

  1. Turn off and lock out the main disconnect before working on the unit.
  2. Strip the signal cable to about 1/2 in (12 mm) and strip the conductors. Crimp fork terminals on the ends.
  3. Open the front panel and remove the electric control box cover.
  4. Run the power and signal cables through the wire outlet.
  5. Connect each fork terminal to its matching terminal and match the wire labels. Tighten each screw firmly.
  6. Check the wiring diagram on the control box cover for the serial number and wire labels.
  7. Clamp the cable so it is not loose and does not pull on the fork terminals.
  8. Keep the interconnection cable away from copper tubing. Keep wires clear of the refrigerant circuit, which can get very hot.
  9. Reattach the electric box cover.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Air Handler codes

Models

DLFLABH36XA3DLFLABH48XA3DLFLABH60XA3DLFSABH18XB3DLFSABH24XB3DLFSABH30XB3DLFSABH36XB3DLFUAAQ18XB3DLFUAAQ24XB3DLFUAAQ30XB3DLFUAAQ36XA3DLFUAAQ36XB3DLFUAAQ48XA3DLFUAAQ60XA3

Source: DLFUAA service manual, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency