Trane Heat Pump: SERVICE flashes on and off at ISU steps 5 and 8, or SERVICE and HEAT flash together
SERVICE flashes on and off at ISU steps 5 and 8, or SERVICE and HEAT flash together on a Trane heat pump: The control flags a mismatch between the JP1 jumper and the installer setup choices.
Applies to: Dual fuel heat pump with gas or oil heat
Common causes of service flashes on and off at isu steps 5 and 8, or service and heat flash together
- JP1 dual fuel jumper setting does not agree with the ISU selections.
How to fix service flashes on and off at isu steps 5 and 8, or service and heat flash together: step by step
- Cut the JP1 jumper for dual fuel applications.
- Recheck installer steps 5 and 8 against the system.
If the unit shows an error code, look it up: Trane Heat Pump codes
Source: Trane XR402 installer's guide 18-HD29D3-4, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.